|
|
17800 Newhope St
Suite B
Fountain Valley
CA
92708
United States
800-222-0074
|
|
Private
|
Biomed was founded in 1994. The founders' collective expertise in chemistry, physics, engineering, and process manufacturing allowed Alpine to develop superior pH catheters for diagnostic use. Since then, we have continually improved our products and processes, making us the number one pH catheter supplier to the major gastroenterology diagnostic medical device companies in the US and Europe.
Although we have grown considerably since 1994, our Fountain Valley headquarters remain a few miles from the original office. All Alpine employees are dedicated to our customers and to maintaining the highest quality standards possible. We are working every day to improve our sensor technologies and bring better diagnostics to the medical world.
Our manufacturing facilities in Asia and the United States give us a unique cost advantage when developing new technology and production. All of our products go through final assembly, quality control, and packaging in the United States to maintain the highest possible quality standards. We are ISO 9002 certified, and are licensed by the FDA to produce medical devices.
|
|
http://www.alpinebiomed.com
|
|
|
|
|
|
|
|
|
|
Konigsberg Solid-State Esophageal Manometry (EM) Catheters and Accessories Product Literature
4 channel Esophageal Manometry Catheter, 4.00 mm diam, circumferential sensor at 2 cm, directional sensors at 7, 12, 17 cm, oriented 120°.
read more...
|
|
Mui Reusable Esophageal Manometry (EM) and Anorectal Manometry Water-Perfused Catheters Product Lite
• Pediatric Esophageal, 3 channel spacing 0-5-10 cm, 3.2 mm diam
• Pediatric Esophageal, 4 channel spacing, 0-3-6-9 cm, 3.2 mm diam
read more...
|
|
Single-Use Anorectal Manometry (ARM) Water-Perfused Catheters Product Literature
• Single Use 8 channel ARM Catheter: Ports at 0, .5, 1, 1.5, 2, 2.5, 3, 3.5 cm, 5 cm tip with silicone balloon (Box of 10)
• Single Use 4 channel ARM Catheter: Ports at 0, 1, 2, 3 cm, 5 cm tip with silicone balloon (Box of 10)
• Single Use 8 channel Vector Volume Catheter: 8 radial ports at 0 cm, 5 cm tip (Box of 10)
• Single Use 4 channel ARM Catheter: 4 radial ports at 0 cm, 5 cm tip with silicone balloon (Box of 10)
• Single Use 8 channel ARM Catheter: Ports at 0, .5, 1, 1.5, 2, 2.5, 3, 3.5 c
read more...
|
|
Single-Use Esophageal Manometry (EM) Water-Perfused Catheters Product Literature
• Single Use 8 channel EM Catheter: ports at 0, 1, 2, 3, 5, 10, 15, 20 cm, 3 cm tip (Box of 10)
• Single Use 8 channel EM Catheter: ports at 0, 5, 10, 15, 20 cm, 5 cm tip, (4 radial ports at 0cm) (Box of 10)
• Single Use 4 channel EM Catheter: ports at 0, 5, 10, 15 cm, 3 cm tip (Box of 10)
• Single Use 4 channel EM Catheter: ports at 0, 3, 6, 9 cm, 3 cm tip, 3.5 mm diam (Box of 10)
• Single Use 4 channel EM Catheter: ports at 0, 5, 10, 15 cm from tip, 3.5 mm diam ( Box of 10)
read more...
|
|
Single-Use Latitude® Air-Charged Catheters and Accessories Product Literature
LATITUDE Air-Charged Single-Use Catheters for Esophageal Motility Studies and Anorectal Manometry.
The Latitude air-charged catheters are today's choice for esophageal and anorectal manometry studies. These catheters are disposable, single-use, eliminating cross-contamination risks, sterilization issues, and downtime in your facility. Every sensor on the EM catheter is circumferential for increased accuracy. Anorectal catheters are available with circumferential or directional sensors. Both
read more...
|
|
VersaFlex™ Disposable pH Catheters Product Literature
VersaFlex catheters are available in two diameters: our standard 4.7 French and the “Large Diameter” (LD) 6.4 French. They are made with internal references and are available in one to four sensors. VersaFlex catheters include a standard RJ-45 connector.
read more...
|
|
|
|
|
|
|