The AccuDrain™ External CSF Drainage
System is used to drain cerebrospinal
fluid (CSF) from the ventricles of the
brain or the lumbar subarachnoid space
to a drainage bag. System components
facilitate CSF drainage, CSF sampling
and Intracranial Pressure (ICP)
monitoring.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
ACCU-FLO Clear Ventricular Catheter, sterile.
Rounded X-ray detectable tantalum tip. X-ray
detectable tantalum mark at 15cm. With 40
inlet holes, four rows of ten holes, 90° apart
|
Company:
Date:
October 25, 2008
|
|
|
|
|
|
|
|
|
|
Made of barium impregnated silicone tubing or
spring imbedded clear silicone tubing, 1.3mm
I.D. x 2.5mm O.D. X-ray detectable. Each
catheter has 24 drainage holes, four rows of six
holes, 90° apart. X-ray detectable tantalum
markings are at the distal 10cm, 20cm, and
30cm.
|
Company:
Date:
October 25, 2008
|
|
|
|
|
|
|
|
|
|
The BACTISEAL® EVD Catheter system is a technically innovative anti-microbial impregnated catheter for external CSF drainage which reduces gram positive bacteria on catheter tube surfaces. Treated with the patented BACTISEAL® Advanced Impregnation Process, it reduces the potential for bacterial colonization on inner lumen and exterior catheter wall.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
Medtronic Neurosurgery external drainage and monitoring (EDM) products meet a variety of needs for CSF drainage and monitoring. From the completely closed drainage and monitoring system of the Becker® EDMS to the ventriculostomy kit -- all products are designed for speed and convenience in emergency situations. All EDM products come with latex-free injection sites, minimizing the chance for adverse patient/personnel reactions to latex.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
A catheter used for percutaneous transluminal coronary angioplasty, used to treat cases where an artery or heart valve is suffering from narrowing or blockage. A catheter incorporating a tiny balloon is introduced into the problem area, and the balloon is inflated, widening the passageway and restoring circulation.
|
Company:
Date:
October 25, 2008
|
|
|
|
|
|
|
|
|
|
CODMAN’s HOLTER System provides both
straight and right angle ventricular catheters.
The right angle catheters are designed for use
when a reservoir is not required. All ventricular
catheters have a 3.1mm O.D. and a 1.5mm
I.D.. All ventricular tips have multiple
perforations.
|
Company:
Date:
October 25, 2008
|
|
|
|
|
|
|
|
|
|
Programmable/Adjustable Pressure Valves
|
Company:
Date:
October 28, 2008
|
|
|
|
|
|
|
|
|
|
Programmable/Adjustable Pressure Valves
|
Company:
Date:
October 28, 2008
|
|
|
|
|
|
|
|
|
|
Codman® Hakim™ Programmable valve Inline with siphonguard offers the ability to optimize the opening pressure of a shunt system before and after implantation. A shunted patient's condition will often change over the course of their trea™ent.
|
Company:
Date:
October 28, 2008
|
|
|
|
|
|